Historical Information
This section describes the configuration and management of historical information, of which there are two types. Metrics about resource usage over time (trends) are enabled with the Metrics.Enabled
setting. More discrete usage events are enabled with the Metrics.Instrumentation
setting. Both settings are true
, by default; to disable either one, set it to false
in your configuration file.
Historical Metrics
Posit Connect uses a separate rserver-monitor
process to record resource (CPU, memory, etc.) usage over time. It is only active when historical metrics are enabled. The customization settings described in the remainder of this section have no effect when Metrics.Enabled
is off.
Historical Metrics Settings
Metrics data is written by default to a set of RRD files. This data is stored by default at /var/lib/rstudio-connect/metrics
. You can specify an alternate data path by using the Metrics.DataPath
setting.
The rserver-monitor
process runs (by default) with the same user account Connect uses to run its processes associated with deployed content. By default, this user account is rstudio-connect
(see the Applications.RunAs
setting). You can specify an alternate user account for the rserver-monitor
process by modifying the Metrics.User
setting.
Posit Connect also supports logging of metrics to Graphite, and it supports disabling its default behavior of logging to RRD. Please see the Metrics configuration appendix for more options for configuring the historical metrics in Connect.
Historical Metrics Process Management
Connect automatically spawns a process (rserver-monitor
) to help maintain historical data. If this process exits, Connect will restart it in an attempt to record as much historical information as possible. Connect will delay restarting rserver-monitor
if it observes rapid, repeated failures.
Since the rserver-monitor
needs permission to write data to the metrics data directory, Connect attempts to ensure the necessary permissions at startup. When Connect starts, it grants ownership of the metrics data directory to the user account that will be used to start rserver-monitor
.
Historical Metrics Process Logging
The rserver-monitor
process logs its output to syslog. If the process is unable to run, you can check the system log (e.g., /var/log/messages
or /var/log/syslog
) for messages.
Historical Events
Posit Connect can record event-style usage information which is intended to answer questions like, “Who used my Shiny app and for how long?” This information is stored in dedicated tables in the database. When using SQLite, this is handled automatically by creating a second database file named connect-instrumentation
. For PostgreSQL, a second, full database URL can be provided in the Postgres.InstrumentationURL
setting. If it is not specified, it will default to the value of Postgres.URL
. This allows you to store the event data in the same place as the rest of the Connect information, in a different schema, or even a different database, whichever meets your needs best. Please see the PostgreSQL section for more details about using Postgres.
There is currently no data retention policy so all data will always be kept. Data retention controls will be added in a future release.
Shiny Application Events
When a user opens a Shiny application, an event containing their user information and the length of their session will be logged to the instrumentation database. It’s important to note that some configuration settings may affect how the ending time for a session is set.
The ended time will always include the duration configured in the
Client.ReconnectTimeout
property. This is 15 seconds, by default.The
Scheduler.ConnectionTimeout
andScheduler.ReadTimeout
values control when an idle session is terminated by Posit Connect. This will, as a side effect, set the ended time for the session.
These events may be retrieved by making use of the “Get Shiny Application Usage” API. The API returns information in pages and provides URLs in each response that may be used as-is to request the next or previous page of information. All data may be retrieved by first invoking the endpoint without next
or previous
parameters to return the first page of results and then repeatedly following the next
link in each response until that link becomes null.
The API may only be used by administrators and publishers. Additionally, publishers may only retrieve information about the Shiny apps that they own.
Optional filters within the request may be used to limit what usage records are returned with each response. Filters are “ANDed” together (i.e. data returned will satisfy all filters).
Application GUIDs may be provided to limit responses to particular applications. A publisher will be implicitly limited to only applications he or she owns. If a publisher asks for information about other content (content owned by someone else), the result will not contain data for that application and will not be reported as an error.
Timestamps may be provided to limit usage information to a more narrow time window of interest. By using the from
or to
filters, either independently or together, the information returned will be limited to applications that were being accessed within that window of time. It’s worth noting that information for an app will be included in such a request if any portion of its usage by a user falls within the specified time window.
The data returned for a Shiny application session includes a version number. As the Connect software has evolved, issues have been identified with how data is recorded. The version number provides an indication of any known issues and are described below.
Version | Issue |
---|---|
0
|
Extraneous records were recorded under some conditions, notably when protocols other than websockets were used. These can be identified by the same value for started and ended . This may adversely affect analyses involving counts or session lengths.
|
1
|
No known issues. |
The min_data_version
filter may be used to control what data to return. The default minimum data version to return is 1
.
Code examples showing how to access this data are in the User Activity API Cookbook recipes. The Connect Server API Reference documents each of the Instrumentation endpoints used by these recipes.
Content Visit Events
When a user visits a document, plot, or application other than a Shiny application, an event will be logged to the instrumentation database noting the time of the visit, the visitor and the content visited.
Requests made to APIs are also recorded as content visit events. Dashboard and open solo visits to APIs may record a hit for the content visit as well as the serving of documentation, depending on how your API is configured. For example, open solo visits to Plumber Swagger documentation and Plumber Swagger example executions are not recorded, but FastAPI serving documentation when a root GET /
is not provided counts as a valid visit.
Visit events are written to the database when the number of hits reaches the configured value of Metrics.InstrumentationBatchSize
(default 200) or the elapsed time reaches the configured value of Metrics.InstrumentationInterval
(default 2s). In the event the Connect process exits or is terminated, those values bound the amount of queued instrumentation data that will not be stored. If needed, you can restore the old immediate-write behavior by configuring Metrics.InstrumentationBatchSize = 1
.
These events may be retrieved by making use of the “Get Content Visits” API. The API returns information in pages and provides URLs in each response that may be used as-is to request the next or previous page of information. All data may be retrieved by first invoking the endpoint without next
or previous
parameters to return the first page of results and then repeatedly following the next
link in each response until that link becomes null.
The API may only be used by administrators and publishers. Additionally, publishers may only retrieve information about the content that they own.
Optional filters within the request may be used to limit what visit records are returned with each response. Filters are “ANDed” together (i.e. data returned will satisfy all filters).
Application GUIDs may be provided to limit responses to particular content. A publisher will be implicitly limited to only content he or she owns. If a publisher asks for information about other content (content owned by someone else), the result will not contain data for that content and will not be reported as an error.
Timestamps may be provided to limit visit information to a more narrow time window of interest. By using the from
or to
filters, either independently or together, the information returned will be limited to content that was visited within that window of time.
The data returned for a visit to content includes a version number. As the Connect software has evolved, issues have been identified with how data is recorded. The version number provides an indication of any known issues and are described below.
Version | Issue |
---|---|
0
|
Extraneous records were recorded under some conditions, notably when content is not rendered to a self-contained page and refers to images, CSS, JavaScript, and the like as files external to the page but within the content. |
1
|
Activity to Plumber APIs and Python applications and APIs was under-counted. Visits were not recorded when the content was hosted within the Posit Connect dashboard. |
2
|
Dashboard visits to Plumber, Voila, Dash, Streamlit, and Bokeh content were over-counted. |
3
|
No known issues. |
The min_data_version
filter may be used to control what data to return. The default minimum data version to return is 3
.
Code examples showing how to access this data are in the User Activity API Cookbook recipes. The Connect Server API Reference documents each of the Instrumentation endpoints used by these recipes.
User Login Events
When a user logs in to the Connect dashboard their user information will be logged to the instrumentation database.
This event information is not currently presented in the dashboard or via an API.
Server Node Session Events
Node session events may be erroneous if you have multiple nodes with the same hostname and do not reconfigure your node name, as explained below.
When a node is started, an event will be logged to the database containing a node name, the server start time, and a periodically-updating heartbeat timestamp indicating the length of the node’s running session. A node that exits cleanly will log true
to the exited_cleanly
column for its session.
If exited_cleanly
is false
, it means either:
The node is still running. In this case, the heartbeat will continue to update.
The node’s
rstudio-connect
process was terminated withSIGKILL
, or the system lost power while the process was running. Confirm this by cross-referencing the node’s log file with the row for the session at issue. The log for that session will end abruptly in this case.The node was terminated with
SIGTERM
orSIGINT
, but did not successfully write to the database before being terminated withSIGKILL
or before the system lost power. Confirm this by cross-referencing the node’s log file, looking specifically for the line beginning withCaught SIGINT/SIGTERM
. The log for that session will end abruptly after that line in this case.The node was terminated with
SIGTERM
orSIGINT
, but couldn’t write to the database for some other reason. Confirm this by cross-referencing the node’s log file, looking specifically forError storing server exit time
. The log for that session will contain that line in this case.
The node name defaults to the node’s hostname, but can be changed using the Server.NodeName
configuration setting or the RSTUDIO_CONNECT_NODE_NAME
environment variable. The node name MUST be unique for every node in your cluster. Posit Connect cannot detect duplicate node names at this time, including the situation where multiple nodes have the same hostname.
The heartbeat timestamp can be changed from its default of 30m
by setting Metrics.InstrumentationServerHeartbeat
to another duration.
This event information is not currently presented in the dashboard or via an API.